November
16
Plate Flooding for Enriched Lysate on Soil Sample C (Lucy P.)
Rationale
Today we will flood webbed plates created on 11/7/18 to create more lysate from Lucy’s phage.
Procedure
- Established an aseptic zone.
- 5 mL of phage buffer was poured onto one previously webbed plate. The process was repeated for another plate The plates were placed on a shaker for 1 hour.
- After 1 hour had passed, the flood lysate was filtered through a 0.22 µm syringe filter and was placed in the fridge for later use.
Observations
The plates that were flooded are shown above. One plate fell off the shaker, causing 5 mL of phage buffer to be added again and the 1 hour long waiting period to be restarted.
Conclusions/Next Steps
8.3 mL of lysate was collected from flooding, which will allow for use in later plaque assays and spot tests in pursuit of a high titer.