Rationale: The purpose of this lab is to flood webbed plates to create more of a high titer lysate.
Description of Procedures:
- The workstation was cleaned using aseptic technique and an ethanol burner was lit.
- 6 ml of phage buffer was added to each of the four webbed plates. The plates were placed on the shaker and allowed to shake for one hour.
- The lysate was collected from the plates and filtered with a 0.22 um syringe filter into a tube labeled LIP 11-20-18 Lysate 3.
- The workstation was cleaned using aseptic technique and materials were properly stored and disposed of.
Observations:
- Plates not fully webbed.
Interpretations/Next Steps:
The procedure was complete. However, the plates were not webbed. Due to this the titer most likely will not increase. The next step will be to perform a titer test.
Webbed Plates and Control: